TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Message displayed
Description
Message is displayed when orderwire mode
change routine is completed. Message displays
active orderwire mode (secure or non-secure)
after change is made.
PLEASE STAND BY
Message is displayed in a transmit config-
uration routine while configuration data
is being transmitted to standby or re-
mote TD-1337(V)/G.
# In generate configuration routines, enter
number (1, 2, or 3) for port interface
type at each port designated by prompt.
NOTES
Prompt only designates active ports.
Inactive ports have a "0" displayed.
Ports 6, 7, and 8 are not displayed.
When one of these ports is active,
it is automatically assigned as a bal-
anced interface.
"UNBALANCED=3" is not displayed
on V3 and V4 models.
PORT OUTPUTS, DEMUX/PORT
# At each port designated by prompt, enter
3=/
1>/
2= /
4= /
DEMUX number (1 to 4) and then enter
5=/
7= /
6= /
PORT number (1 to 8).
8= /
NOTE
PORT OUTPUTS (1 to 8) displayed as
part of message are your local mux
ports. DEMUX data you enter is your
demux receiving SG that contains data
to be routed to local mux port being
designated by prompt. PORT data you
enter is remote mux port in SG that
contains data to be routed to local mux
port being designated by prompt.
PORT RATES IN KBS, INACTIVE=0
# At each port designated by prompt, enter
3=
4=
1>
2=
assigned port rate. Each designated port
5=
6=
8=
7=
must have a port rate (in kb/s) or a "0" entered.
2-19