TM 11-7025-221-1O
2-6. List of Message Displays - Continued.
Message Displays - Continued
Description
Message displayed
Message is displayed in display system config-
uration, download local configuration, download
to non-nodal, or system mode change routines
if appropriate configuration data is not in the
selected memory.
Message is displayed when a system mode
change to preliminary, memory 1, or memory
2 mode is attempted and orderwire configuration
data has not been entered. System mode
change routine is aborted.
# Message is displayed if CNCE or external
NO PORTS AVAILABLE, REENTER >
standard was selected as the timing source
IF CNCE OR EXTERNAL STANDARD=1
and there are no ports with the proper rates
IF NOT, SLAVE=2 MASTER=3
and formats. Recheck configuration data that
was supplied to you.
NVM CHECKSUM ERROR
# Message can be displayed when a system
mode change routine is performed.
MEMORY
*MUX or RMUX (1-4) is displayed.
NOTE
This display indicates that something
has altered contents of NVM in
memory 1 or memory 2. Display also
identifies problem is local mux (MUX
displayed) or one of Rmux's (RMUX
1 - 4 is displayed) configurations in
NVM.
Inform proper authority that problem
exists. If authorized, reenter config-
uration data and then perform sys-
tem mode change routine.
If MUX is displayed, local mux and
Rmux configurations must be en-
tered in designated memory (1 or 2).
If RMUX (1 - 4) is displayed, only
that Rmux configuration need be en-
tered in designated memory (1 or 2).
..
Enter "1" if display orderwire configura-
ORDW CONFIG SELECTION
>
DISPLAY= 1 GENERATE=2
tion routine is being performed or enter "2" if
generate orderwire configuration routine is being
performed.
2-18