TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Description
Message displayed
ENTER CALL #
Enter call number of TD-1337(V)/G or CNCE
>
16KBS ORDW IS IN
MODE
being called. Message also displays mode
(secure or non-secure) in which orderwire is ac-
tive.
NOTE
Secure mode used for Vinson call or
non-secure mode used for H-250 call.
>
ENTER CALL TYPE
Enter number (1 or 2) for call type selected
16KBS ORDW = 1 ANDVT=2
for orderwire call.
NOTE
Message is not applicable to and is not
displayed for V1 and V2 models.
EXTERNAL TIMING SOURCES
# At each port designated by prompt, enter
"1" when port is assigned as an external
CNCE OR EXT STD PORTS= 1 OTHERS= 0
1>
timing source. "0" is assigned to a port that
2=
3=
4=
5=
6=
7=
8=
is not to be used as an external timing source.
This message is displayed when you have se-
lected a routine that cannot be performed.
Examples:
Select an orderwire routine when TD-1337(V)/G
is operating in inactive or TD-976 mode,
Select receive control telemetry routine when
"T" not displayed.
Select answer orderwire call routine when "0"
not displayed.
Select display VCXO status routine when TD-
1337(V)/G is operating in a master or slave
timing mode.
Enter number (1, 2, or 3) for configuration
>
GENERATION MODE
I
routine type to be performed.
NEW CONFIGURATION=1 CONTINUE=2
EDIT EXISTING CONFIGURATION=3
HARDWARE LOAD ABORTED
Message is displayed when a hardware load
operation has been aborted.
2-15