TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Description
Message displayed
# At each port designated by prompt, enter
TD-754 MUX OPTION
"1" if port is to use TD-754 mux option.
INACTIVE=0 ACTIVE= 1
Otherwise, enter "0".
PORT 5>
PORT 7=
NOTE
This message is only displayed in V1
T I M I N G SOURCE SELECTION >
# Enter number (1, 2, or 3) of timing
IF CNCE OR EXTERNAL STANDARD=1
source selected for configuration.
IF NOT, SLAVE= 2 MASTER=3
Message is displayed when a transmit configu-
TRANSMIT COMPLETE
ration routine is performed and remote TD-
1337(V)/G has automatically acknowledged that
transmission has been received. (This does not
mean that remote operator has performed re-
ceive control telemetry routine to accept or abort
transmission.)
1
I
# Enter number (1, 2, or 3) to select transmit
configuration routine to be performed.
TRANSMIT UNSUCCESSFUL
Message is displayed when download to standby
routine is performed and standby TD-1337(V)/G
does not acknowledge transmission.
Message is displayed when a transmit con-
figuration routine is performed and remote TD-
1337(V)/G does not acknowledge receiving the
transmission. Message identifies which demux's
do not receive an acknowledge from associated
remote TD-1337(V)/G receiving transmission.
Message can be caused by:
Remote TD-1337(V)/G is turned off.
Remote TD-1337(V)/G is operating in same
memory (1 or 2) that is designated in trans-
mitted configuration.
System-level transmission problem.
NOTE
V1 and V3 models can display up to
4 demux's, V2 and V4 models only dis-
play demux 1 when no acknowledge
occurs.
2-23