TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Description
Message displayed
CESE MAJOR OLD
STEP
One of message headings that appear when
alarms recall routine is performed. Heading can
be followed by lines of diagnostic information.
NOTE
Message is not applicable to and is not
displayed for V1 and V2 models.
CESE MINOR
One of message headings that appear when
STEP
alarms recall routine is performed. Heading can
be followed by lines of diagnostic information.
NOTE
Message is not applicable to and is not
displayed for V1 and V2 models.
CESE TELEMETRY EQUIP ID >
# Enter CESE telemetry equipment identification
number assigned to your TD-1337(V)/G.
NOTE
Message is not applicable to and is not
displayed for V1 and V2 models.
CESE TLM PATCH OPTION
>
# Enter CESE telemetry patch option se-
PATCH LOCAL TO COND Dl MODEM= 1
lected for your TD-1337(V)/G.
PATCH DEMUX1 TO COND Dl MODEM=2
NOTE
Message is not applicable to and is not
displayed for V1 and V2 models.
CNCE ENTRY REQUIRED, REENTER
# CNCE or external timing source was
CNCE OR EXT STD PORTS=1 OTHERS=0
previously selected prior to performing
1> 2= 3= 4= 5= 6= 7= 8=
this step. You did not select any CNCE or ex-
ternal sources in this step (entered all O's). If
you are using CNCE or external source, con-
figuration must have at least one "1" entry in
step.
COMPOSITE RATE LESS THAN 16KBS
You have entered a configuration that has a
GENERATION FUNCTION TERMINATED
composite rate that is less than 16 kb/s. Routine
is automatically aborted. Either incorrect rate(s)
were entered when performing routine or in-
correct configuration data was supplied.
2-13