TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Description
Message displayed
STEP
One of message headings that appear when
TSSP MAJOR OLD
alarms recall routine is performed. Heading can
be followed by lines of diagnostic information.
TSSP MINOR
STEP
One of message headings that appear when
alarms recall routine is performed. Heading can
be followed by lines of diagnostic information.
Message is displayed when VCXO status
display routine is performed and VCXO frequen-
cy response is in range. (VCXO is considered
in range when a value between +6 and -6 is
displayed.)
Message is displayed when VCXO status
display routine is performed and VCXO frequen-
OUT OF RANGE
VCXO OUTPUT=
cy response is out of range. (VCXO is consid-
ered out of range when a value of + 7 or 7
is displayed.)
VERIFY MEMORY
LOADING >
# Enter "1" to accept orderwire config-
ACCEPT= 1 ABORT=2
uration data entered during generate orderwire
configuration routine. Enter "2" to abort (not use)
I
configuration data. (This step verifies that op-
erator wants orderwire configuration data en-
tered into memory or aborted.)
# Enter "1" to accept configuration data
entered during local mux configuration,
Rmux minimum configuration, or Rmux config-
uration for downloading routines. Enter "2" to
abort (not use) configuration data. (This step ver-
ifies that operator wants configuration data en-
tered into selected memory or wants configu-
ration data aborted. )
16KBS ORDERWIRE OPTION >
# Enter "1" to use option or enter "O"
INACTIVE=0 ACTIVE= 1
if option is not used.
2-25