TM 11-7025-221-10
2-6. List of Message Displays - Continued.
Message Displays - Continued
Message displayed
Description
# Enter number of demux (1 - 4) receiving
supergroup containing data for dedicated user.
NOTE
Message is not displayed in V2 and
V4 models. (Demux 1 automatically en-
tered.)
16/32 KBS USER MISMATCH
Message is displayed when rate assignment
(16 or 32) for dedicated user is not the
MEMORY LOAD ABORTED
same between local and associated remote TD-
I
1337(V)/G. This message also indicates that
memory loading is aborted.
I
16/32 KBS USER OPTION
>
# Enter "0" if option is not used. Enter
INACTIVE=0
"l" if 16KBS option is used or "2" if
16KBS ACTIVE=1 32KBS ACTIVE=2
32KBS option is used.
5 MIN AUDIBLE ALARM INHIBIT >
# Enter "1" to activate inhibit function.
ACTIVATE= 1 CLEAR= 2
Enter "2" to clear (turn-off) inhibit function before
normal 5-minute inhibit cycle is completed.
2-26