TM 11-7025-221-10
2-27. Generate Local Mux Configuration Routine (V1/V2 Models) - Continued.
Local Mux Configuration Data Requirements (V1/V2 Models) - Continued
Message heading
Step
Definitions
No.
data required
At each port, enter "1" if port is desig-
15
EXTERNAL TIMING SOURCES
nated as an external timing source. Enter
"0" for each port not designated as a tim-
Port
5--
Port
1
--
ing source.
Port
6--
Port
2
--
Port
7--
Port
3
--
NOTES
Port
8--
Port
4
--
q Ports 3 through 8 not used in V2 model.
q This step is used if CNCE or external standard
was previously selected as the timing source
("1" entered in step 14).
Enter number of demux ("1", "2", "3",
16
SLAVE TIMING SOURCE
or "4") receiving SG containing timing
from remote TD-1337(V)/G.
Entry:
_
NOTES
q This step is used if "2" was entered in step
14.
q This step is not used in V2 model.
Enter number of 1/4-miIe cable reels (1 to 8
17
COND Dl GROUP MODEM CABLE
for data rates up to 576 kb/s or 1 to 4 for
data rates of 1024 or 1152 kb/s) used with group
Entry:
--
modem input. Enter "0" when none are used.
NOTE
This step is used if "2" was entered in step 7
for port 1, 3, or 5.
2-62