TM 11-7025-221-10
2-26. Display System Configuration Routine.
Perform the following procedures to display local mux or an active Rmux configuration data contained in
memory 1 or memory 2. These procedures can be performed without affecting normal equipment operation.
NOTES
When a message is displayed that you do not understand, go
1337(V)/G are listed in alphabetical order. The operator action
associated with each display is described in the paragraph.
Start with step 1 and perform the action in the procedures as
directed. Messages that appear on the display are shown in bold
type.
Display System Configuration Routine
Step
Operator action/message display
Press FUNC key (one or two times) until SELECT FUNCTION is displayed. Then press SYSTEM
1
CONF key.
2
CONFIGURATION SELECTION >
DISPLAY= 1 GENERATE=2 TRANSMIT=3
Press "1" key and then press ENTR key.
3
Press "l" or "2" key and then press ENTR key.
1
4
LOCAL/REMOTE MUX SELECTION >
LOCALMUX=0 RMUX 1=1 RMUX 2=2
RMUX 3=3 RMUX 4=4
Press (0 - 4) key to select configuration to be displayed and then press ENTR key.
NOTE
If local mux or Rmux selected is not configured, the routine is terminated
and the following message is displayed. If this message is displayed, go
to step 6.
NO DATA IN SELECTED MEMORY
2-58