TM 11-7025-221-10
2-29. Generate Rmux Minimum Configuration Routine - Continued.
Rmux Minimum Configuration Data Requirements - Continued
Message heading/
Step
Definitions
data required
No.
10
16/32 KBS USER OPTION
Enter "0" if option is not used, "1" if
option is used and rate is 16 kb/s, or "2"
if option is used and rate is 32 kb/s.
Entry:
_
b. Procedures. Perform the following procedures to enter Rmux minimum configuration data in memory
1 or memory 2.
NOTES
q This q symbol in a step indicates that operator will enter con-
figuration data supplied by authority that originated the config-
uration.
q When a message is displayed that you do not understand, go
1337(V)/G are listed in alphabetical order. The operator action
associated with each display is described in the paragraph.
q Start with step 1 and perform the action in the procedures as
directed. Messages that appear on the display are shown in bold
type.
Rmux Minimum Configuration Routine
Operator action/message display
Step
1
Press FUNC key (one or two times) until SELECT FUNCTION is displayed. Then press SYSTEM
CONF key.
2
Press "2" key and then press ENTR key.
3
Press "1" key and then press ENTR key.
2-77