TM 11-7025-221-10
2-21. Alarms Recall Routine - Continued.
Alarms Recall Routine - Continued
Operator action/message displayed
Step
4
TSSP MAJOR OLD
STEP
Record any diagnostic information displayed. Then press STEP key.
5
Record any status point information displayed. Then press STEP key.
6
Record any diagnostic information displayed. Then press STEP key.
7
Record any status point information displayed. Then press STEP key.
ALARMS RECALL COMPLETE
8
Check that above message is displayed.
Check that ALARMS MINOR indicator is off. Other ALARMS indicators will be lit if a previously
detected fault still exists. If ALARMS MINOR indicator is lit, refer to troubleshooting procedures
in chapter 3 for operator action.
Press CLR key to clear display.
9
2-49