TM 11-7025-221-20
2-3. Rack Mounting Requirements - Continued.
c. Space Requirements. Approximately 24 inches of clearance is required directly in front of the rack.
When the TD-1337(V)/G is pulled out on the slides, there must be sufficient clearance to service the sides,
top, bottom, and rear of the unit. The rack must contain adequate space to make the necessary cable
connections, with service loops, to the rear of the TD-1337(V)/G.
d. Location in Rack. When mounting the TD-1337(V)/G in a rack, choose a location in the rack that
is not at the extreme bottom or top of the rack. Operator actions are accomplished at the keyboard and
display located on the front of the TD-1337(V)/G. Organizational maintenance tasks will require access
to the top of the TD-1337(V)/G when it is pulled out on the slides.
2-4. Interface Connector Data.
All external connections are made to connectors J1 through J12 located cm the rear of the TD-1337(V)/G.
As explained in paragraph 1-10, each TD-1337(V)/G model has a different complement of rear connectors.
The following chart provides data as to what type connector will mate with each TD-1337(V)/G rear connector.
Paragraph 2-5 lists the signals for each pin of each rear connector.
TD-1337(V)/G Connector Data
TD-1337(V)/G connector
Mating
Function
No.
Type
connector type
MS27467T23B21S
Supergroups
MS27656T23B21P
J1
Remote interface
MS27467T13B35SA
MS27656T13B35PA
J2
MS27467T17B8S
Conditioned diphase (group modem)
MS27656T17B8P
J3
MS27467T17B35SA
MS27656T17B35PA
CESE telemetry, 2.4 DVOW, and DLED
J4
interface (black) (V3 and V4 models only)
MS3114E-12-3P
MS3116E-12-3S
Ac power input
J5
MS27656T17B35P
MS27467T17B35S
Balanced NRZ groups 1 thru 4
J6
MS27656T17B35P
MS27467T17B35S
Balanced NRZ groups 5 thru 8 (V1 and V3
J7
models only)
CESE status point inputs (V3 and V4 models
MS27656T21B35P
MS27467T21B35S
J8
only)
MS27656T21B16P
Unbalanced NRZ (TD-660) groups 1 and 2
MS27467T21B16S
J9
(V1 and V2 models only)
MS27656T9B35P
DLED interface (red) (V3 and V4 models
MS27467T9B35S
J10
only)
MS27656T21B16P
MS27467T21B16S
J11
Unbalanced NRZ (TD-660) groups 3 and 4
(V1 model only)
MS27467T13635S
Vinson interface, 16/32 kb/s dedicated user,
J12
MS27656T13B35P
and remote alarms
2-2