TM 11-7025-221-1O
Supergroups. Multiplexer (roux) combines group inputs, dedicated user input (if used), 16 kb/s DVOW
input if used), 2.4 kb/s DVOW input, and CESE telemetry into a single output SG. Output SG
rate is always the total of the following:
Sum of active group input rates
If used, 16 kb/s or 32 kb/s for dedicated user
If used, 16 kb/s for 16 kb/s DVOW
8 kb/s for overhead (includes 2 kb/s of CESE data and 2.4 kb/s DVOW)
A demultiplexer (demux) provides for demultiplexing the received SG.
Group Inputs/Outputs. Connection points exist for 5 group inputs/outputs. From these, a maximum
of 4 may be selected for use (4 ports max available). The above chart defines which type(S)
of group inputs/outputs (formats) can be accommodated by each port. Listed below the chart are
the possible data rates for each format. As indicated by note 2, group data rates of 1024 and
1152 kb/s require the use of two ports.
The received SG is demultiplexed (recombined) into its composite parts by the demux. Applicable
group data is then switched to its designated port for output to the group. Thus, inputs and outputs
for a given group use the same numbered port.
1-18